heating:inventum
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| heating:inventum [2022/12/20 13:36] – [User Menu] oscar | heating:inventum [2022/12/20 13:39] (current) – [Installation Menu] oscar | ||
|---|---|---|---|
| Line 49: | Line 49: | ||
| ^Menu ^Setting^Description^Our Value^ | ^Menu ^Setting^Description^Our Value^ | ||
| |0 - 1|Sub Menu - Extra Settings||| | |0 - 1|Sub Menu - Extra Settings||| | ||
| - | |:::|5 - XX|Ventilation Setting 1 (value x 10 = 60-120)| | + | |:::|5 - XX|Ventilation Setting 1 (value x 10 = 60-120)|10| |
| - | |:::|6 - XX|Ventilation Setting 2 (value x 10 = 120-230)| | + | |:::|6 - XX|Ventilation Setting 2 (value x 10 = 120-230)|21| |
| - | |:::|7 - XX|Ventilation Setting 2 (value x 10 = 150-320)| | + | |:::|7 - XX|Ventilation Setting 2 (value x 10 = 150-320)|32| |
| - | |:::|8 - X |Priority (2=CV 3=WW)| | + | |:::|8 - X |Priority (2=CV 3=WW)|2| |
| - | |:::|9 - X |Warmwater aan of uit (alleen combi 50) \\ 0=warmwater uit 1=warmwater aan| | + | |:::|9 - X |Warmwater aan of uit (alleen combi 50) \\ 0=warmwater uit 1=warmwater aan|1| |
| |:::| - 0|Terug naar fabrieksinstelling. \\ 0=terug naar fabrieksinstelling 1=nieuwe instellingen actief| | |:::| - 0|Terug naar fabrieksinstelling. \\ 0=terug naar fabrieksinstelling 1=nieuwe instellingen actief| | ||
| |1 - XX|Ventilatietimer stand 3 – timertijd in minuten (0 tot 60)|| | |1 - XX|Ventilatietimer stand 3 – timertijd in minuten (0 tot 60)|| | ||
| - | |2 - X|Backlight 0 = uit / 1 = automatisch / 2 = continue aan|| | + | |2 - X|Backlight 0 = uit / 1 = automatisch / 2 = continue aan||1| |
| |3 - XX|Instelling CV1 binnenluchtthermostaat op zomerstand. \\ Instelbaar van 14 tot 17 °C|| | |3 - XX|Instelling CV1 binnenluchtthermostaat op zomerstand. \\ Instelbaar van 14 tot 17 °C|| | ||
| - | |4 - XX|Instelling CV 1 binnenluchtthermostaat op winterstand. \\ Instelbaar van 15 tot 23 °C|| | + | |4 - XX|Instelling CV 1 binnenluchtthermostaat op winterstand. \\ Instelbaar van 15 tot 23 °C||21| |
| + | |5 - XX|Onbekend||5| | ||
| |t - 1|Klokinstelling – instelling van juiste kloktijd|| | |t - 1|Klokinstelling – instelling van juiste kloktijd|| | ||
| |t - 2|Start Night Clock)|| | |t - 2|Start Night Clock)|| | ||
| Line 73: | Line 74: | ||
| ^Menu ^Setting^Description^^Our Value^ | ^Menu ^Setting^Description^^Our Value^ | ||
| |0 _ 0|0 = XX|Ventilatie volume warmtepomp (value x 10 =m3/h). || | |0 _ 0|0 = XX|Ventilatie volume warmtepomp (value x 10 =m3/h). || | ||
| - | |:::|:::| **__Standaard 19. Bij vorst verhogen naar 21__**|| | + | |:::|:::| **__Standaard 19. Bij vorst verhogen naar 21__**||19| |
| - | |:::|6 = X|Bedrijfsmodus. 0=warmtepomp, | + | |:::|6 = X|Bedrijfsmodus. 0=warmtepomp, |
| |:::| = 1|0 = fabrieksinstelling, | |:::| = 1|0 = fabrieksinstelling, | ||
| |0 _ 1|Status Temperatures|||| | |0 _ 1|Status Temperatures|||| | ||